The system collects GC time of the Presto Coordinator process every 30 seconds. This alarm is generated when the GC time exceeds the threshold (exceeds 5 seconds for three consecutive times). You can change the threshold by choosing System > Configure Alarm Threshold > Service > Presto > Coordinator > Presto Process Garbage Collection Time > Garbage Collection Time of the Coordinator Process on MRS Manager. This alarm is cleared when the Coordinator process GC time is less than or equal to the threshold.
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
44005 |
Major |
Yes |
Parameter |
Description |
---|---|
ServiceName |
Service for which the alarm is generated. |
RoleName |
Role for which the alarm is generated. |
HostName |
Host for which the alarm is generated. |
If the GC time of the Coordinator process is too long, the Coordinator process running performance will be affected and the Coordinator process will even be unavailable.
The heap memory of the Coordinator process is overused or inappropriately allocated, causing frequent occurrence of the GC process.
For MRS 1.8.10 or earlier, log in to MRS Manager and choose Alarms.
None