diff --git a/docs/sdrs/umn/ALL_META.TXT.json b/docs/sdrs/umn/ALL_META.TXT.json index 1400ed298..0bcdaa02b 100644 --- a/docs/sdrs/umn/ALL_META.TXT.json +++ b/docs/sdrs/umn/ALL_META.TXT.json @@ -27,7 +27,7 @@ "code":"2", "des":"Storage Disaster Recovery Service (SDRS) provides disaster recovery (DR) services for many cloud services, such as Elastic Cloud Server (ECS) and Elastic Volume Service (", "doc_type":"usermanual", - "kw":"SDRS,What Is SDRS?,Service Overview,User Guide", + "kw":"What Is SDRS?,Service Overview,User Guide", "search_title":"", "metedata":[ { diff --git a/docs/sdrs/umn/en-us_topic_0110273585.html b/docs/sdrs/umn/en-us_topic_0110273585.html index 255540da1..fa3469a7b 100644 --- a/docs/sdrs/umn/en-us_topic_0110273585.html +++ b/docs/sdrs/umn/en-us_topic_0110273585.html @@ -10,7 +10,7 @@

Procedure

  1. Log in to the management console.
  2. Click Service List and choose Storage > Storage Disaster Recovery Service.

    The Storage Disaster Recovery Service page is displayed.

  3. In the pane of the protection group for which the protected instance specifications are to be modified, click Protected Instances.

    The operation page for the protection group is displayed.

  4. On the Protected Instances tab, locate the row containing the target protected instance, click More in the Operation column, and choose Modify Production Site Server Specifications or Modify DR Site Server Specifications from the drop-down list.

    Figure 1 Modifying specifications
    -

  5. In the displayed dialog box, select new server type, vCPU, and memory specifications.
  6. (Optional) If you need to modify the specifications of both the production site server and DR site server, select Modify the specifications of both the production and DR site servers. After you select this item, the system will modify the specifications of both the production site server and DR site server to the same specifications.

    Figure 2 Modifying the specifications of both the production site server and DR site server
    +

  7. In the displayed dialog box, select new server type, vCPU, and memory specifications.
  8. (Optional) If you need to modify the specifications of both the production site server and DR site server, select Modify the specifications of both the production and DR site servers. After you select this item, the system will modify the specifications of both the production site server and DR site server to the same specifications.

    Figure 2 Modifying the specifications of both the production and DR site servers

    This item is deselected by default, indicating that the system modifies the specifications of only the production site server or DR site server.

  9. Click OK.

    To ensure proper server running, do not perform any operations to the servers during specification modifications.

    diff --git a/docs/sdrs/umn/en-us_topic_0110981899.html b/docs/sdrs/umn/en-us_topic_0110981899.html index bf83eb866..abca68fee 100644 --- a/docs/sdrs/umn/en-us_topic_0110981899.html +++ b/docs/sdrs/umn/en-us_topic_0110981899.html @@ -12,7 +12,7 @@

    Computing

    Constraints on server types:

    -
    • GPU-accelerated, FPGA-accelerated, and C6 ECSs are not supported.
      • Kunpeng ECSs are not supported.
      • x86 ECSs with GPU-accelerated and FPGA-accelerated types are not supported.
      +
      • GPU-accelerated, FPGA-accelerated, C6, C9, S9, I9, and M9 ECSs are not supported.
        • Kunpeng ECSs are not supported.
        • x86 ECSs with GPU-accelerated and FPGA-accelerated types are not supported.
      diff --git a/docs/sdrs/umn/en-us_topic_0288665269.html b/docs/sdrs/umn/en-us_topic_0288665269.html index d11d04751..51b20f1c1 100644 --- a/docs/sdrs/umn/en-us_topic_0288665269.html +++ b/docs/sdrs/umn/en-us_topic_0288665269.html @@ -8,7 +8,12 @@ -

      2025-10-20

      +

      2026-02-26

      + +

      Modified the constraints.

      + + +

      2025-10-20

      Optimized some descriptions.