This API is used to specify whether to delete a NIC when the BMS is deleted or the NIC is detached.
PUT /v1/{project_id}/baremetalservers/{server_id}/os-interface/{port_id}
Table 1 lists the parameters.
Parameter |
Mandatory |
Description |
|---|---|---|
project_id |
Yes |
Specifies the project ID. For details about how to obtain the project ID, see Obtaining a Project ID. |
server_id |
Yes |
Specifies the BMS ID. You can obtain the BMS ID from the BMS console or by calling the Querying BMSs (Native OpenStack API). |
port_id |
Yes |
Specifies the BMS NIC ID. |
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
interface_attachment |
Yes |
Object |
Specifies the attribute to be modified. For details, see Table 2. |
{
"interface_attachment" : {
"delete_on_termination": false
}
}
None
Returned Values |
Description |
|---|---|
200 |
The request has been successfully processed. |
For details about other returned values, see Status Codes.
See Error Codes.