<a name="EN-US_TOPIC_0000001188323672"></a><a name="EN-US_TOPIC_0000001188323672"></a>
<h1 class="topictitle1">GTM Parameters</h1>
<div id="body1560396205733"><div class="section" id="EN-US_TOPIC_0000001188323672__section4348132224212"><h4 class="sectiontitle">log_min_messages</h4><p id="EN-US_TOPIC_0000001188323672__p19283113417249"><strong id="EN-US_TOPIC_0000001188323672__b1473143918380">Parameter description</strong>: Specifies which level of messages will be written into server logs. Each level covers all the levels following it. The lower the level is, the fewer messages will be written into the log.</p>
<div class="notice" id="EN-US_TOPIC_0000001188323672__note1050162518380"><span class="noticetitle"><img src="public_sys-resources/notice_3.0-en-us.png"> </span><div class="noticebody"><p id="EN-US_TOPIC_0000001188323672__p14501225123814">If the values of <strong id="EN-US_TOPIC_0000001188323672__b13921131293915">client_min_messages</strong> and <strong id="EN-US_TOPIC_0000001188323672__b13823151711396">log_min_messages</strong> are the same, they indicate different levels.</p>
</div></div>
<p id="EN-US_TOPIC_0000001188323672__p14664049102617"><strong id="EN-US_TOPIC_0000001188323672__b21028242403">Type</strong>: SUSET</p>
<p id="EN-US_TOPIC_0000001188323672__p1593324419363"><strong id="EN-US_TOPIC_0000001188323672__en-us_topic_0059778452_en-us_topic_0058967791_b842352706105940_3">Valid values</strong>: enumerated values. Valid values are <strong id="EN-US_TOPIC_0000001188323672__b842352706151558">debug</strong>, <strong id="EN-US_TOPIC_0000001188323672__b117541526711463">debug5</strong>, <strong id="EN-US_TOPIC_0000001188323672__b169673200711463">debug4</strong>, <strong id="EN-US_TOPIC_0000001188323672__b47865843211463">debug3</strong>, <strong id="EN-US_TOPIC_0000001188323672__b43948333211463">debug2</strong>, <strong id="EN-US_TOPIC_0000001188323672__b91509763011463">debug1</strong>, <strong id="EN-US_TOPIC_0000001188323672__b189415270011463">info</strong>, <strong id="EN-US_TOPIC_0000001188323672__b95437598411463">log</strong>, <strong id="EN-US_TOPIC_0000001188323672__b152313787911463">notice</strong>, <strong id="EN-US_TOPIC_0000001188323672__b88787696711463">warning</strong>, <strong id="EN-US_TOPIC_0000001188323672__b189315041711463">error</strong>, <strong id="EN-US_TOPIC_0000001188323672__b135240131311463">fatal</strong>, and <strong id="EN-US_TOPIC_0000001188323672__b47496871311463">panic</strong>. For details about the parameters, see <a href="dws_04_0915.html#EN-US_TOPIC_0000001233883395__ta1ceaf79532d439ead5e098dee6f7b7e">Table 1</a>.</p>
<p id="EN-US_TOPIC_0000001188323672__p72831934142415"><strong id="EN-US_TOPIC_0000001188323672__en-us_topic_0059779078_aa0277e6ac9fa4c50b8128665f2d4a6f7">Default value</strong>: <strong id="EN-US_TOPIC_0000001188323672__b842352706162652">warning</strong></p>
</div>
<div class="section" id="EN-US_TOPIC_0000001188323672__section7347145954215"><h4 class="sectiontitle">enable_alarm</h4><p id="EN-US_TOPIC_0000001188323672__p1228373416241"><strong id="EN-US_TOPIC_0000001188323672__en-us_topic_0059779120_ab44f2b063aaf4beb8d6f6aea8f04c31b">Parameter description</strong>: Specifies whether to enable the alarm detection thread to detect the fault scenarios that may occur in the database.</p>
<p id="EN-US_TOPIC_0000001188323672__p1177418489281"><strong id="EN-US_TOPIC_0000001188323672__b1518124924015">Type</strong>: POSTMASTER</p>
<p id="EN-US_TOPIC_0000001188323672__p23703394282"><strong id="EN-US_TOPIC_0000001188323672__b1317093684117">Value range</strong>: Boolean</p>
<ul id="EN-US_TOPIC_0000001188323672__ul193381523191911"><li id="EN-US_TOPIC_0000001188323672__li73385231190"><strong id="EN-US_TOPIC_0000001188323672__b84235270618710">on</strong>: Alarm detection thread is enabled.</li><li id="EN-US_TOPIC_0000001188323672__li933872341914"><strong id="EN-US_TOPIC_0000001188323672__b84235270618720">off</strong>: Alarm detection thread is disabled.</li></ul>
<p id="EN-US_TOPIC_0000001188323672__p428373472417"><strong id="EN-US_TOPIC_0000001188323672__b7626171312315">Default value</strong>: <strong id="EN-US_TOPIC_0000001188323672__b16627513102317">on</strong></p>
</div>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="dws_04_0883.html">GUC Parameters</a></div>