Reviewed-by: gtema <artem.goncharov@gmail.com> Co-authored-by: guoyanyan <guoyanyan3@huawei.com> Co-committed-by: guoyanyan <guoyanyan3@huawei.com>
14 KiB
Configuring a User-defined VLAN (Ubuntu)
This section uses Ubuntu 16.04 LTS (Xenial Xerus x86_64) as an example to describe how to configure a user-defined VLAN for BMSs.
The configuration methods of other Ubuntu OSs are similar to that of Ubuntu 16.04 LTS (Xenial Xerus x86_64).
- Use a key or password to log in to the BMS as user root.
- On the BMS CLI, run the following command to check the NIC information:
ip link
Information similar to the following is displayed:
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN mode DEFAULT group default qlen 1 link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 2: eth0: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 8888 qdisc mq master bond0 state UP mode DEFAULT group default qlen 1000 link/ether fa:16:3e:1c:35:37 brd ff:ff:ff:ff:ff:ff 3: eth1: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 8888 qdisc mq master bond0 state UP mode DEFAULT group default qlen 1000 link/ether fa:16:3e:1c:35:37 brd ff:ff:ff:ff:ff:ff 4: enp129s0f0: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000 link/ether f4:4c:7f:3f:da:07 brd ff:ff:ff:ff:ff:ff 5: enp129s0f1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000 link/ether f4:4c:7f:3f:da:08 brd ff:ff:ff:ff:ff:ff 6: bond0: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 8888 qdisc noqueue state UP mode DEFAULT group default qlen 1000 link/ether fa:16:3e:1c:35:37 brd ff:ff:ff:ff:ff:ff - Run the following command to check whether the /etc/udev/rules.d/ directory contains the 80-persistent-net.rules file:
ll /etc/udev/rules.d/ | grep 80-persistent-net.rules
- Run the following command to copy the /etc/udev/rules.d/70-persistent-net.rules file and name the copy as /etc/udev/rules.d/80-persistent-net.rules.
cp -p /etc/udev/rules.d/70-persistent-net.rules /etc/udev/rules.d/80-persistent-net.rules
- Configure the udev rules:
Add the NICs and their MAC addresses obtained in step 2, except lo, eth0, eth1, and bond0, to the /etc/udev/rules.d/80-persistent-net.rules file. This ensures that the names and sequence of NICs will not change after the BMS is restarted.
vim /etc/udev/rules.d/80-persistent-net.rules
The modification result is as follows:
SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="e8:4d:d0:c8:99:5b", NAME="eth0" SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="e8:4d:d0:c8:99:5c", NAME="eth1" SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="f4:4c:7f:3f:da:07", NAME="enp129s0f0" SUBSYSTEM=="net", ACTION=="add", DRIVERS=="?*", ATTR{address}=="f4:4c:7f:3f:da:08", NAME="enp129s0f1"After the modification, press Esc, enter :wq, save the configuration, and exit.
- Run the following command to copy the /etc/network/interfaces.d/50-cloud-init.cfg file to generate the /etc/network/interfaces.d/60-cloud-init.cfg file:
cp -p /etc/network/interfaces.d/50-cloud-init.cfg /etc/network/interfaces.d/60-cloud-init.cfg
- Run the following command to edit the /etc/network/interfaces.d/60-cloud-init.cfg file of devices enp129s0f0 and enp129s0f1:
vim /etc/network/interfaces.d/60-cloud-init.cfg
Edit the file as follows:
auto enp129s0f0 iface enp129s0f0 inet manual bond_mode 1 bond-master bond1 bond_miimon 100 mtu 8888 auto enp129s0f1 iface enp129s0f1 inet manual bond_mode 1 bond-master bond1 bond_miimon 100 mtu 8888 auto bond1 iface bond1 inet static bond_miimon 100 bond-slaves none bond_mode 1 address 10.10.10.3 netmask 255.255.255.0 hwaddress f4:4c:7f:3f:da:07 mtu 8888
Where,
- enp129s0f0 and enp129s0f1 are the NICs that bear the user-defined VLAN.
- hwaddress is the MAC address of enp129s0f0.
- Change the value of address to the IP address allocated to bond1. If the IP address planned for the user-defined VLAN does not conflict with the VPC network segment, you can plan the IP address as needed, only to ensure that BMSs communicating through the user-defined VLAN are in the same network segment as the user-defined VLAN.
- Set the value of netmask to the subnet mask of the IP address configured for bond1.
Set values of other parameters. For example, set mtu to 8888, bond_miimon to 100, and bond_mode to 1.
After the modification, press Esc, enter :wq, save the configuration, and exit.
- Run the following commands to restart the network:
ifup enp129s0f0
ifup enp129s0f1
- Run the following commands to check the NIC device status and whether the bond1 configuration file takes effect:
ip link
ifconfig
- Perform the preceding operations to configure other BMSs.
- After all BMSs are configured, ping the IP addresses of other BMSs from each BMS.