Reviewed-by: Sarda, Priya <prsarda@noreply.gitea.eco.tsi-dev.otc-service.com> Co-authored-by: fanqinying <fanqinying@huawei.com> Co-committed-by: fanqinying <fanqinying@huawei.com>
27 KiB
Creating a VPC Attachment
Function
This API is used to create a VPC attachment for an enterprise router.
URI
POST /v3/{project_id}/enterprise-router/{er_id}/vpc-attachments
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
project_id |
Yes |
String |
Project ID |
er_id |
Yes |
String |
Enterprise router ID |
Request Parameters
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
X-Client-Token |
No |
String |
Idempotence identifier Minimum: 1 Maximum: 64 |
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
vpc_attachment |
Yes |
VpcAttachmentCreateRequest object |
VPC attachment |
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
vpc_id |
Yes |
String |
VPC ID. The value contains a maximum of 36 characters in UUID format with hyphens (-). |
name |
Yes |
String |
VPC attachment name. The value can contain 1 to 64 characters, including letters, digits, underscores (_), hyphens (-), and periods (.). Minimum: 1 Maximum: 64 |
virsubnet_id |
Yes |
String |
VPC subnet ID. The value contains a maximum of 36 characters in UUID format with hyphens (-). |
description |
No |
String |
Supplementary information. The value can contain no more than 255 characters and cannot contain angle brackets (< or >). Minimum: 0 Maximum: 255 |
auto_create_vpc_routes |
No |
Boolean |
The default value is false. If the value is set to true, a route with the enterprise router as the next hop will be automatically added to the route tables of the VPC. This parameter can only be enabled when a VPC attachment is created. Default: false |
ipv6_enable |
No |
Boolean |
The default value is false. If the value is set to true, IPv6 is enabled. This parameter is not supported. Default: false |
tags |
No |
Array of Tag objects |
Tag information |
Parameter |
Mandatory |
Type |
Description |
|---|---|---|---|
key |
No |
String |
Tag key. The key:
Minimum: 1 Maximum: 128 |
value |
No |
String |
Tag value. The value:
Minimum: 0 Maximum: 255 |
Response Parameters
Status code: 202
Parameter |
Type |
Description |
|---|---|---|
X-Client-Token |
String |
Idempotence identifier |
Parameter |
Type |
Description |
|---|---|---|
vpc_attachment |
VpcAttachmentDetails object |
VPC attachment |
request_id |
String |
Request ID |
Parameter |
Type |
Description |
|---|---|---|
id |
String |
VPC attachment ID |
name |
String |
VPC attachment name |
vpc_id |
String |
VPC id |
virsubnet_id |
String |
VPC subnet ID |
auto_create_vpc_routes |
Boolean |
The default value is false. If this parameter is set to true, routes with this enterprise router as the next hop and 10.0.0.0/8, 172.16.0.0/12, and 192.168.0.0/16 as the destinations will be automatically added to the route tables of the VPC. Default: false |
state |
String |
VPC attachment status. The value can be pending, available, modifying, deleting, deleted, failed, initiating_request, rejected, pending_acceptance, freezed, or invalid. |
created_at |
String |
Creation time in the format YYYY-MM-DDTHH:mm:ss.sssZ |
updated_at |
String |
Update time in the format YYYY-MM-DDTHH:mm:ss.sssZ |
tags |
Array of Tag objects |
Tag information |
description |
String |
Supplementary information about the VPC attachment |
project_id |
String |
Project ID |
vpc_project_id |
String |
ID of the project that the VPC belongs to |
ipv6_enable |
Boolean |
The default value is false. If the value is true, IPv6 is enabled for the VPC attachment. This parameter is not supported for now. Default: false |
route_synchronization |
RouteSynchronization object |
Route synchronization configuration. This parameter is not supported. |
frozen_scene |
String |
Frozen reason. The reason can be account arrears, public security, and violations of laws and regulations. This parameter is not supported. |
Parameter |
Type |
Description |
|---|---|---|
key |
String |
Tag key. The key:
Minimum: 1 Maximum: 128 |
value |
String |
Tag value. The value:
Minimum: 0 Maximum: 255 |
Parameter |
Type |
Description |
|---|---|---|
route_synchronization_enable |
Boolean |
Whether to enable route synchronization. |
vpc_route_table_type |
String |
VPC route table where routes are to be synchronized. |
route_type |
String |
Type of the route to be synchronized. |
conflict_policy |
String |
A conflict policy that specifies whether to synchronize routes with the same destination and next hop to the VPC route table. |
Example Requests
Creating a VPC attachment named vpc-atta
POST https://{erouter_endpoint}/v3/08d5a9564a704afda6039ae2babbef3c/enterprise-router/4ab54142-7c92-48ad-8288-77727a231052/vpc-attachments
{
"vpc_attachment" : {
"name" : "vpc-atta",
"vpc_id" : "b715e131-3371-4e17-a2de-4f669e24439a",
"virsubnet_id" : "aacdc21d-90f9-45ef-ab48-80ec1bbe15b8"
}
}
Example Responses
Status code: 202
Accepted
{
"vpc_attachment" : {
"id" : "6f83b848-8331-4271-ac0c-ef94b7686402",
"name" : "vpc-atta",
"vpc_id" : "b715e131-3371-4e17-a2de-4f669e24439a",
"virsubnet_id" : "aacdc21d-90f9-45ef-ab48-80ec1bbe15b8",
"project_id" : "08d5a9564a704afda6039ae2babbef3c",
"ipv6_enable" : "false,",
"state" : "pending",
"auto_create_vpc_routes" : false,
"created_at" : "2020-03-11T15:13:31Z",
"updated_at" : "2020-03-11T15:13:31Z"
},
"request_id" : "915a14a6-867b-4af7-83d1-70efceb146f9"
}
Status Codes
Status Code |
Description |
|---|---|
202 |
Accepted |
Error Codes
See Error Codes.