Reviewed-by: Hasko, Vladimir <vladimir.hasko@t-systems.com> Co-authored-by: Li, Qiao <qiaoli@huawei.com> Co-committed-by: Li, Qiao <qiaoli@huawei.com>
13 KiB
Updating Alarm Configuration
Functions
This API allows you to update alarm configuration, such as whether a certain type of alarms will be received, and whether alarms are received through SMS messages or emails.
URI
Request
- Parameter description
Parameter
Mandatory
Type
Description
warn_config
Yes
List data structure
Alarm configuration
topic_urn
Yes
String
ID of an alarm group
display_name
Yes
String
Description of an alarm group
- Data structure description of warn_config
Parameter
Mandatory
Type
Description
antiDDoS
Yes
Boolean
DDoS attacks
bruce_force
No
Boolean
Brute force cracking (system logins, FTP, and DB)
remote_login
No
Boolean
Alarms about remote logins
weak_password
No
Boolean
Weak passwords (system and database)
high_privilege
No
Boolean
Overly high rights of a database process
back_doors
No
Boolean
Webshells
waf
No
Boolean
Reserved
send_frequency
No
Integer
Possible values:
- 0: indicates that alarms are sent once a day.
- 1: indicates that alarms are sent once every half hour.
Example
{
"warn_config": {
"antiDDoS": true,
"bruce_force": false,
"remote_login": false,
"weak_password": false,
"high_privilege": false,
"back_doors": false,
"waf": false
},
"topic_urn": "urn:smn:eu-de:67641fe6886f43fcb78edbbf0ad0b99f:test_soft",
"display_name": "group_1"
}
Status Code
For details, see Status Code.