<a name="en-us_topic_0122528555"></a><a name="en-us_topic_0122528555"></a>
|
|
|
|
<h1 class="topictitle1">Performing a DR Drill</h1>
|
|
<div id="body1531999471001"><div class="section" id="en-us_topic_0122528555__section171315582320"><h4 class="sectiontitle">Scenarios</h4><p id="en-us_topic_0122528555__p91618033318">DR drills can be used to simulate fault scenarios, develop emergency recovery solutions, and verify whether the solutions are applicable and effective. Existing services will not be affected during a DR drill. When a fault occurs, you can use the solutions to rapidly restore services, enhancing service continuity.</p>
|
|
<p id="en-us_topic_0122528555__p598930122518">SDRS provides the DR drill function. You can perform DR drills in a drill VPC (different from the VPC of the DR site). This function allows you to use the disk snapshots of the DR site servers to create drill servers with the server specifications and disk types same as the DR site servers.</p>
|
|
<div class="note" id="en-us_topic_0122528555__note20483133513441"><img src="public_sys-resources/note_3.0-en-us.png"><span class="notetitle"> </span><div class="notebody"><p id="en-us_topic_0122528555__p64557191303">After the DR drill server is created, the production site server and DR drill server will independently run at the same time (data will not be synchronized between these two servers).</p>
|
|
</div></div>
|
|
<p id="en-us_topic_0122528555__p97681816112810">To ensure that a failover can be properly performed if a disaster happens, you are recommended to perform DR drills regularly to verify that:</p>
|
|
<ul id="en-us_topic_0122528555__ul88242642913"><li id="en-us_topic_0122528555__li128282615293">The production site data and DR site data are consistent at the moment when you create a DR drill.</li><li id="en-us_topic_0122528555__li1682626152920">The services at the DR site can run properly after a failover.<div class="fignone" id="en-us_topic_0122528555__fig135261922851"><span class="figcap"><b>Figure 1 </b>Performing a DR drill</span><br><span><img id="en-us_topic_0122528555__image34730501789" src="en-us_image_0288665327.png"></span></div>
|
|
</li></ul>
|
|
</div>
|
|
<div class="section" id="en-us_topic_0122528555__section1613910364214"><h4 class="sectiontitle">Notes</h4><ul id="en-us_topic_0122528555__ul8606151212421"><li id="en-us_topic_0122528555__li1231711587815">When you use a created drill VPC to create a drill, the subnet ACL rule of the drill VPC will be different from that of the VPC of the protection group. You need to manually set them to be the same one if needed.</li><li id="en-us_topic_0122528555__li116071912114215">When you create a DR drill, if the VPC of the protection group has a customized routing table and subnets configured, the corresponding routing table will not be automatically created for the drill VPC. You need to manually create it if needed.</li><li id="en-us_topic_0122528555__li1322195311148">If the DR site server runs Windows and uses the key login mode, ensure that the key pair of the DR site server exists when you create a DR drill. Otherwise, the DR drill server may fail to create, resulting in the DR drill creation failure.<div class="note" id="en-us_topic_0122528555__note123512812439"><img src="public_sys-resources/note_3.0-en-us.png"><span class="notetitle"> </span><div class="notebody"><p id="en-us_topic_0122528555__p12236389432">If the key pair of the DR site server has been deleted, create a key pair with the same name.</p>
|
|
</div></div>
|
|
</li><li id="en-us_topic_0122528555__li09071551194019">When you create a DR drill, if the DR site server runs Linux and uses the key login mode, the key pair information will not be displayed on the details page of the DR drill server after the DR drill server is created. You can use the key pair of the DR site server to log in to the DR drill server.</li><li id="en-us_topic_0122528555__li1685105125012">After you create a DR drill, modifications to the <strong id="en-us_topic_0122528555__b178018296462">Hostname</strong>, <strong id="en-us_topic_0122528555__b67883295469">Name</strong>, <strong id="en-us_topic_0122528555__b15788102916469">Agency</strong>, <strong id="en-us_topic_0122528555__b1478822974617">ECS Group</strong>, <strong id="en-us_topic_0122528555__b37891329184610">Security Group</strong>, <strong id="en-us_topic_0122528555__b1778920295465">Tags</strong>, and <strong id="en-us_topic_0122528555__b2790129114618">Auto Recovery</strong> configurations of the DR site server before the drill will not synchronize to the DR drill server. You can log in to the management console and manually add the configuration items to the drill server.</li><li id="en-us_topic_0122528555__li18284122185317">If the synchronization progress of replication pairs in the protection group is not 100%, the created DR drill server may fail to start. You are advised to perform a DR drill after all replication pairs are synchronized.</li></ul>
|
|
</div>
|
|
<div class="section" id="en-us_topic_0122528555__section67593181295"><h4 class="sectiontitle">Prerequisites</h4><ul id="en-us_topic_0122528555__ul19475131019563"><li id="en-us_topic_0122528555__li0301715105613">The protection group is in the <strong id="en-us_topic_0122528555__b73399720414">Available</strong>, <strong id="en-us_topic_0122528555__b153401377413">Protecting</strong>, <strong id="en-us_topic_0122528555__b2340157640">Failover complete</strong>, <strong id="en-us_topic_0122528555__b8341971641">Enabling protection failed</strong>, <strong id="en-us_topic_0122528555__b113421471844">Disabling protection failed</strong>, <strong id="en-us_topic_0122528555__b93432714411">Switchover failed</strong>, <strong id="en-us_topic_0122528555__b43440719418">Re-enabling protection failed</strong>, or <strong id="en-us_topic_0122528555__b5344570412">Failover failed</strong> state.</li><li id="en-us_topic_0122528555__li3185374356">Do not perform a DR drill before the first time data synchronization between the production site server and DR site server completes. Otherwise, the drill server may not start properly.</li></ul>
|
|
</div>
|
|
<div class="section" id="en-us_topic_0122528555__section37751719193414"><h4 class="sectiontitle">Procedure</h4><ol id="en-us_topic_0122528555__ol2989153814717"><li id="en-us_topic_0122528555__li9223419142715"><span>Log in to the management console.</span></li><li id="en-us_topic_0122528555__li12972105114527"><span>Click <strong id="en-us_topic_0122528555__b208842046523">Service List</strong> and choose <strong id="en-us_topic_0122528555__b9893144125216">Storage</strong> > <strong id="en-us_topic_0122528555__b289484195214">Storage Disaster Recovery Service</strong>.</span><p><p id="en-us_topic_0122528555__en-us_topic_0108180805_p45581331134216">The <strong id="en-us_topic_0122528555__b17315111341">Storage Disaster Recovery Service</strong> page is displayed.</p>
|
|
</p></li><li id="en-us_topic_0122528555__li84211239334"><span>In the pane of the protection group to which a DR drill is to be added, click <strong id="en-us_topic_0122528555__b1941420911470">DR Drills</strong>.</span><p><p id="en-us_topic_0122528555__p18473824191114">The operation page for the protection group is displayed.</p>
|
|
</p></li><li id="en-us_topic_0122528555__li15636173715436"><span>On the <strong id="en-us_topic_0122528555__b11815151324712">DR Drills</strong> tab, click <strong id="en-us_topic_0122528555__b1882315138476">Create DR Drill</strong>.</span><p><p id="en-us_topic_0122528555__p234174413430">The <strong id="en-us_topic_0122528555__b9858181544714">Create DR Drill</strong> dialog box is displayed.</p>
|
|
</p></li><li id="en-us_topic_0122528555__li1280494716437"><span>Configure <strong id="en-us_topic_0122528555__b1291316254479">Name</strong> and <strong id="en-us_topic_0122528555__b19920132515471">Drill VPC</strong>.</span><p>
|
|
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" id="en-us_topic_0122528555__table17278611195315" frame="border" border="1" rules="all"><caption><b>Table 1 </b>Parameter description</caption><thead align="left"><tr id="en-us_topic_0122528555__row18279121110532"><th align="left" class="cellrowborder" valign="top" width="17.001700170017003%" id="mcps1.3.4.2.5.2.1.2.4.1.1"><p id="en-us_topic_0122528555__p1673616279539">Parameter</p>
|
|
</th>
|
|
<th align="left" class="cellrowborder" valign="top" width="60.33603360336033%" id="mcps1.3.4.2.5.2.1.2.4.1.2"><p id="en-us_topic_0122528555__p6737152714535">Description</p>
|
|
</th>
|
|
<th align="left" class="cellrowborder" valign="top" width="22.662266226622663%" id="mcps1.3.4.2.5.2.1.2.4.1.3"><p id="en-us_topic_0122528555__p197371427125317">Example Value</p>
|
|
</th>
|
|
</tr>
|
|
</thead>
|
|
<tbody><tr id="en-us_topic_0122528555__row1527915119539"><td class="cellrowborder" valign="top" width="17.001700170017003%" headers="mcps1.3.4.2.5.2.1.2.4.1.1 "><p id="en-us_topic_0122528555__p57403279534">Name</p>
|
|
</td>
|
|
<td class="cellrowborder" valign="top" width="60.33603360336033%" headers="mcps1.3.4.2.5.2.1.2.4.1.2 "><p id="en-us_topic_0122528555__p177411527185315">DR drill name</p>
|
|
</td>
|
|
<td class="cellrowborder" valign="top" width="22.662266226622663%" headers="mcps1.3.4.2.5.2.1.2.4.1.3 "><p id="en-us_topic_0122528555__p374242715310">DR drill servername</p>
|
|
</td>
|
|
</tr>
|
|
<tr id="en-us_topic_0122528555__row1627921117530"><td class="cellrowborder" valign="top" width="17.001700170017003%" headers="mcps1.3.4.2.5.2.1.2.4.1.1 "><p id="en-us_topic_0122528555__p274392717539">Drill VPC</p>
|
|
</td>
|
|
<td class="cellrowborder" valign="top" width="60.33603360336033%" headers="mcps1.3.4.2.5.2.1.2.4.1.2 "><p id="en-us_topic_0122528555__p0743927135319">VPC that used for a DR drill. It cannot be the same as the VPC of the DR site server. The value can be <strong id="en-us_topic_0122528555__b18613125212470">Automatically create</strong> or <strong id="en-us_topic_0122528555__b1062011529477">Use existing</strong>.</p>
|
|
<ul id="en-us_topic_0122528555__ul3372115552310"><li id="en-us_topic_0122528555__li737225515235"><strong id="en-us_topic_0122528555__b10397175415473">Automatically create</strong>: The system automatically creates a drill VPC and subnets for the protection group.</li><li id="en-us_topic_0122528555__li137255519235"><strong id="en-us_topic_0122528555__b162051556194716">Use existing</strong>: The system uses an existing VPC as the drill VPC. If you select to use an existing VPC, the subnet CIDR block of the drill VPC must be consistent with that of the production group VPC.</li></ul>
|
|
<div class="note" id="en-us_topic_0122528555__note1476474313238"><span class="notetitle"> NOTE: </span><div class="notebody"><p id="en-us_topic_0122528555__p7764843112313">The drill VPC cannot be the same as the VPC of the protection group.</p>
|
|
</div></div>
|
|
</td>
|
|
<td class="cellrowborder" valign="top" width="22.662266226622663%" headers="mcps1.3.4.2.5.2.1.2.4.1.3 "><p id="en-us_topic_0122528555__p4744172725315">vpc-f9f7</p>
|
|
</td>
|
|
</tr>
|
|
</tbody>
|
|
</table>
|
|
</div>
|
|
</p></li><li id="en-us_topic_0122528555__li567975719477"><span>Click <strong id="en-us_topic_0122528555__en-us_topic_0170796126_b168421590392">OK</strong>.</span><p><p id="en-us_topic_0122528555__p153101214196">After a DR drill is created, you can log in to the DR drill server and check whether services are running properly.</p>
|
|